8-14
Installation and Maintenance
V
olume
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2
Hardware Error T
ypes and Remedies (continued)
Error T
ype:Name PriorityRemedySource
28:ACP
Err
or Works
requesting an
error be logged in the
W
orks Hardware Error
Table
Log onto W
orks
and list the Hardware
Error T
able. Refer to the W
orks
Installation
and Maintenance Manual
, Maintenance
chapter.
3
29:
DMA T
imeout Non-maskable
interrupt
Contact your technical support center
. 3
30:Arbitration
Timeout
Non-maskable
interrupt
Contact your technical support center
. 3
31:Contr
ol BUS
Error
Non-maskable
interrupt
Contact your technical support center
. 3
32:
CPU Copr
ocessor
Error
Error logged by
coprocessor interrupt
routines and by
coprocessor T
ask
Contact your technical support center
. 2
DATA-1 = TYPE OF ERROR THAT OCCURRED IN THE COPROCESSOR
01 = COPROCESSOR INITIALIZATION ERROR
DATA-2
gives the reason.
DATA-2 =
3D = DUAL PORT RAM READ/WRITE TEST FAILED
3E = DUAL PORT RAM VERIFY TEST FAILED
3F = STATIC RAM READ/WRITE TEST FAILED
40 = STATIC RAM VERIFY TEST FAILED
41 = UNEXPECTED INTERRUPT RECEIVED BY
COPROCESSOR
42 = UNEXPECTED NMI RECEIVED BY
COPROCESSOR
43 = COPROCESSOR EXECUTED A WILD JUMP
44 = TIMED OUT WAITING FOR COPROCESSOR
READY
02 = TIMEOUT WAITING FOR COPROCESSOR DMA CHANNEL 1 TO
COMPLETE
03 = TIMEOUT WAITING FOR COPROCESSOR DMA CHANNEL 2 TO
COMPLETE
04 = COPROCESSOR-DETECTED ERROR ON DMA CHANNEL 1
05 = COPROCESSOR-DETECTED ERROR ON DMA CHANNEL 2
Vista de pagina 383